HUIFENG automatic roof ventilation
|
|
Based on the convection theory, HUIFENG 300、500、880 automatic roof ventilations adopt the pressure and temperature margin between indoor and outdoor and nature air as dynamic, and could continuously working for 24 hours to out put the heat , humidity or polluted air indoor; no electricity is needed, and is with no noise which really realize power saving and environment protection. In developed country , this type ventilations have populated for more than ten years; in our country, with the much more steel structured building appearing, the installation of natural ventilation will be more and more.
|
Working theory of natural ventilation:
With generated centrifugal power from turning of impeller by the power of wind, the air could happen to flow, as the blades of the ventilation are very thin and light, so just breeze could drive them to rotate. When the rotation of turbo, centrifugal power could be generated, which will output the heat, fume or humidity air. After the outputting of air, there will be a low pressure district below the turbo, which is called chimney effect. With the rotation of turbo, the fresh air outdoors will flow in, the air exchanging purpose will reach. |
automatic roof ventilation Features:
Continuously running ,durable, weatherproof, erosion control, power saving , environment protection, no noise, no electricity required, continuously rotating with or without wind, no need to repaired, stainless fan case, small volume , easily installed, and no fire danger

|
Needed amount of ventilators calculation formula 1.firstly, measure the volume of the room(length X width X height)
2.secondly, identify the air exchanging times every hour according the usage of building.
3.thirdly, look out the air exchanging capacity of ventilators referring to the stable
4.according the regular wind speed supplied by observatory: |
|
numbers of ventilators= |
room volumem3X air exchanging times/hr |
|
| indoor air exchanging capacity(M3/hr)(note: depend on the type) |
|
| HUIFENG300 natural power ventilator |
HUIFENG300 natural power ventilator features:
●High humidity air outputting efficiency
According to the theory of hydromechanics, and designed scientifically, this type ventilators adopt waved type arc welded turbine blades and excellent low resistance high efficient bearing, making ventilator could continuously work under the 2KM/h speed breeze, and output the polluted indoor air.
●Enforced and erosion control. Assured ten years quality guarantee.
High grade Stainless steel ventilator housing is weathertight and erosion controlled.
Fine total sealed low resistance bearing is durable and lubricated , repairelessness.
●Easily and conveniently be installed.
As adopting special angle variable duct, this type ventilation could change their angles rapidly to suit roofs with different slopes (0-22.5). no fixed size much more lower the installation cost.
They are suitable to civil building, factory , workshop , garage and etc.
●This type ventilations adopt fine lubricant bearing, they work with no noise, no vibration, power saving, and without pollution, keeping the environment protection tendency. ●Shaft and bearing
Adopting grate quality low resistant total sealed bearing, no liberation is needed. Main shaft is made of no. 45 steel, erosion control.
●Blades
Wave type arc blades are designed according to the hydromechanics theory, enlarging the touched area and angles of fans with wind, even in breeze , rotation power could be obtained by blades, avoiding the return flow of air. Taking use of the air from all direction, the rotation speed of top turbo could be increased, reaching the weatherproof and air outputting effect. As wave type blades are adopted, the hardness of machinery is larger, pressure bearing capacity is the best in homogeny products. |
| 300 natural power ventilator Performance parameter |
air velocity m/s |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
type |
throat sizemm |
height mm |
air exchanging volume per hour |
300 |
300 |
500 |
8 |
16 |
68 |
127 |
187 |
353 |
667 |
1684 |
2475 |
|
| HUIFENG880 natural powered ventilator |
 |
Features of HUIFENG 300 natural ventilation:
●High humidity air outputting efficiency
According to the theory of hydromechanics, and designed scientifically, this type ventilators adopt waved type arc welded turbine blades and excellent low resistance high efficient bearing, making ventilator could continuously work under the 2KM/h speed breeze, and output the polluted indoor air.
●Enforced and erosion control. Assured ten years quality guarantee
igh grade Stainless steel ventilator housing is weathertight and erosion controlled.
Fine total sealed low resistance bearing is durable and lubricated , repairelessness.
●Easily and conveniently be installed.
As adopting special angle variable duct, this type ventilation could change their angles rapidly to suit roofs with different slopes (0-22.5). no fixed size much more lower the installation cost.
●This type ventilations adopt fine lubricant bearing, they work with no noise, no vibration, power saving, and without pollution, keeping the environment protection tendency.
●Shaft and bearing
Adopting grate quality low resistant total sealed bearing, no liberation is needed. Main shaft is made of no. 45 steel, erosion control.
●Blades
Wave type arc blades are designed according to the hydromechanics theory, enlarging the touched area and angles of fans with wind, even in breeze, rotation power could be obtained by blades, avoiding the return flow of air. Taking use of the air from all direction, the rotation speed of top turbo could be increased, reaching the weatherproof and air outputting effect. As wave type blades are adopted, the hardness of machinery is larger, pressure bearing capacity is the best in homogeny products. |
| Performance parameter of 880 type natural powered ventilator |
|
Installation instruction

Note: avoid set ventilators in mess flow place or the low roof which is near wall, the distance between each ventilator should more than 3m. special ventilators are required in hot district. |
1、location
In ideal condition, ventilation should be installed close to the ridge. Antiwater plate should be set on the roof; the up-canted edge of it should be set 10cm into the ridge metal cover.
2、Cutting hole:
Taking the inside hole of antiwater fix plate as sample, you should draw the outline of the hole. Then use roof cutter to finish the cutting of hole. Repair and furbish the cut edge. Then cut the warm keeping sponge according “米”shape , throw away part of warm keeping sponge, then stuff warm keeping sponge with aluminum foil between steel plate and the other part of warm keeping sponge.
3. stick antiwater puddle band and antiwater silicon glue
Stick antiwater puddle on the connected zone between antiwater plate and ridge cover. Stick antiwater puddle on the two side of the integrated wave climax , tear up the top paper layer and smear antiwater silicon glu between the plug and color steel plate.
4、Fix the antiwater basing plate.
Fix the antiwater basing plate on the wall using more than ten screws or rivet.
5.Installation of angle variable duct.
Fix the angle variable duct on the basing plate, turn the rotatable part of the duct, adjust the duct 90°measured by gradienter, making the top of angle variable duct to be horizontal. After regulation, draw sign with color pen on the rotatable part of the duct and the part between duct and basing plate.
6、fix the angle variable duct
Using more than four ??? screw, fix the duct on the basing plate. Using mental splint and aluminum rivet fix the two rotatable sides together and along the line drawn before.
7、Fix the top of turbo on the angle variable duct
Set the four supports of turbo top into the preleft chases, and then fix it on the duct with four screws.
8、 Check and adjustment
Make sure that the screw and rivet are fixed; the turbo top working stable and is not distorted caused by transportation or installation. Then smear antiwater silicon glue on the plug and around basing plate. |
|
|
|
| |
|
|
|
| |
Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net |
Office in Beijing Address: Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun |
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu |
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an |
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone:13589940048
Contact : An Shuwei |
|
|
|
|