NBL back flow fiber
glass cooling tower As the motor capacity
is comparative lower than the other homogenous
products, all the cooling towers we produced are
power saving. The water temperature of low noise
and super low noise types generally could be
reduced 3-8℃,
suitable for the air condition cooling and other
general water cooling.
Based on the low noise
cooling tower, super low noise tower adopts
another series noise control methods. The
standard noise level is~5dB(A)lower
than the relevant low noiseproducts. They suit to the quiet required
places like hotels, hospitals, public building
and the places around civil residence. The basic
apparatus, companion pipeline, motor voltage are
the same with relative low noise type products,
the cooling water volume is also the same. The moderate and high
temperature industry type cooling tower could
reduced 10-25℃ of water temperature. Diameter of tower, flow
volume, air pressure, power and filling material
are added of this type. They are suitable for
the high temperature water cooling in industry.
This industry tower is with high grade
thermodynamic, the customers could choose a much
suitable one. Meaning of codes: DBNL3-100type,D
low noise, B fiber glass, Nback flow style,
L-cooling tower, 3-the third design ,100-flow
volume 100m3/h in standard condition,
GBNL3-100type, G-for industry, high temperature
cooling, CDBNL3-100 ,CDsuper low noise.
Parameter of DBL3
series super low noise fiber glass back flow
cooling tower:
TypeParameter
Water volume when T=28℃m3/h
Water volume when T=27℃m3/h
Flow volume m3/h
Diameter of fan blade(mm)
Power(KW)
Weight(kg)
Pressure(104Pa)
Noise(dB)
Diameter(Dm)
Δt=5℃
Δt=8℃
Δt=5℃
Δt=8℃
State
weight
Weight
during running
D
DBNL3-12
12
9
15
10
7200
700
0.6
206
484
1.96
54.0
1.5
DBNL3-20
20
15
24
17
12400
800
0.8
230
544
2.00
54.0
1.5
DBNL3-30
30
22
35
27
18000
1200
0.8
406
956
2.21
55.0
1.8
DBNL3-40
40
30
46
34
21500
1200
1.1
478
1118
2.60
55.0
1.8
DBNL3-50
50
37
57
44
28000
1400
1.5
596
1480
2.65
55.0
2.1
DBNL3-60
60
44
68
51
32300
1400
1.5
642
1592
2.90
56.0
2.1
DBNL3-70
70
51
79
60
39200
1600
2.2
790
2064
2.78
56.0
2.5
DBNL3-80
80
61
92
70
43400
1600
2.2
875
2243
3.03
56.5
2.5
DBNL3-100
100
74
114
86
56000
1800
3.0
973
3064
2.86
57.0
3.0
DBNL3-125
125
92
142
108
67200
1800
4.0
1063
3290
3.15
58.0
3.0
DBNL3-150
150
112
171
129
84000
2400
4.0
1695
4125
2.90
58.5
3.6
DBNL3-175
175
131
200
150
94000
2400
5.5
1835
4461
3.15
59.5
3.6
DBNL3-200
200
153
231
180
112000
2800
5.5
2132
5592
3.01
60.0
4.2
DBNL3-250
250
186
283
215
134300
2800
7.5
2344
6365
3.26
61.0
4.2
DBNL3-300
300
225
334
260
168000
3400
7.5
3558
9229
3.50
61.0
5.0
DBNL3-350
350
267
395
304
187400
3400
11.0
3860
9906
3.75
61.5
5.0
DBNL3-400
400
301
455
341
224000
3800
11.0
4300
12086
3.60
62.0
5.9
DBNL3-450
450
343
514
387
242000
3800
11.0
4646
13464
3.85
62.0
5.9
DBNL3-500
500
375
576
427
280000
4200
15.0
5768
16258
3.70
62.0
6.6
DBNL3-600
600
454
680
516
302200
4200
18.5
6570
18360
4.20
63.0
6.6
DBNL3-700
700
528
790
600
39350
5000
18.5
6915
23194
3.95
63.0
7.6
DBNL3-800
800
590
890
685
408000
5000
22.0
7983
25982
4.45
63.0
7.6
DBNL3-900
900
685
1035
790
505200
6000
22.0
8934
32568
4.25
63.5
8.6
DBNL3-1000
1000
783
1139
880
510300
6000
30.0
10560
36420
4.75
64.0
8.6
Instruction:
1.The noise level is measured
in standard point D, tower diameter long,
and 1.5m above the ground.
2.This type is designed when
watery ball temperature T=28℃, flow-in water temperature t1=37℃,flow-out water
temperature t2=32℃, that is the reduced water temperature isΔt=5℃,
near to t2-t=4℃.
3.when t=28℃,Δt=5℃ and
8℃,t2=32℃ and
T=27℃,Δt=5℃ and 8℃,t2=32℃ cooled water volume could be referred from the
table. Another volume should be referred
from thermodynamic curve.
4. water pressure
refers to the one from pipeline connection
. 1kgt/cm2=9.8×104Pa, so the water
pressures of this type is between 0.2 to
0.49 kgt/cm2.
Parameter of DBL3
series super low noise fiber glass back flow
cooling tower
TypeParameter
Water volume when T=28℃m3/h
Water volume when T=27℃m3/h
Dimesion
Flow volume m3/h
Diameter(mm)
Power(kw)
Weight(kg)
Pressure 104Pa
Noise(dB)
Diameter
(Dm)
Δt=5℃
Δt=8℃
Δt=5℃
Δt=8℃
MaxHeight
Max Diameter
State
weight
Weight
during running
D
10m
16m
DBNL3-12
12
9
15
10
2972
1600
7200
700
0.6
306
584
1.96
50.0
37.1
33.5
1.5
DBNL3-20
20
15
24
17
3062
2000
12400
800
0.8
330
644
2.00
50.0
36.3
32.6
1.5
DBNL3-30
30
22
35
27
3281
2400
18000
1200
0.8
546
1100
2.21
51.0
39.5
35.9
1.8
DBNL3-40
40
30
46
34
3781
2400
21500
1200
1.1
618
1258
2.60
51.0
39.5
35.9
1.8
DBNL3-50
50
37
57
44
3816
2800
28000
1400
1.5
756
1640
2.65
51.0
40.7
37.1
2.1
DBNL3-60
60
44
68
51
4066
2800
32300
1400
1.5
950
1752
2.90
52.0
41.7
38.1
2.1
DBNL3-70
70
51
79
60
4152
3300
39200
1600
2.2
998
2272
2.78
52.0
43.0
39.0
2.5
DBNL3-80
80
61
92
70
4403
3300
43400
1600
2.2
1083
2451
3.03
52.5
43.5
39.5
2.5
DBNL3-100
100
74
114
86
4440
3900
56000
1800
3.0
1230
3322
2.86
53.0
46.0
42.0
3.0
DBNL3-125
125
92
142
108
4690
3900
67200
1800
4.0
1320
3422
3.15
54.0
46.7
43.4
3.0
DBNL3-150
150
112
171
129
4765
4600
84000
2400
4.0
2045
4475
2.90
54.0
47.5
44.1
3.6
DBNL3-175
175
131
200
150
5015
4600
94300
2400
5.5
2182
4808
3.15
55.0
48.5
45.1
3.6
DBNL3-200
200
153
231
180
5194
5700
112000
2800
5.5
2663
6123
3.01
55.0
49.6
46.3
4.2
DBNL3-250
250
186
283
215
5444
5700
134300
2800
7.5
2875
6892
3.26
56.0
50.6
47.3
4.2
DBNL3-300
300
225
334
260
5713
6400
168000
3400
7.5
4132
9805
3.50
56.0
51.8
48.5
5.0
DBNL3-350
350
267
395
304
5963
6400
187400
3400
11.0
4434
10479
3.75
56.5
52.3
49.0
5.0
DBNL3-400
400
301
455
841
6269
7400
224000
3800
11.0
4995
12782
3.60
57.0
53.8
50.7
5.9
DBNL3-450
450
343
514
387
6519
7400
242000
3800
11.0
5341
14160
3.85
57.0
53.8
50.7
5.9
DBNL3-500
500
375
576
427
5890
8200
280000
4200
15.0
6612
17102
3.70
57.0
55.0
51.9
6.6
DBNL3-600
600
454
680
516
7390
8200
302200
4200
18.5
7414
19204
4.20
68.0
56.0
52.4
6.6
Instruction:
1.The noise level is less
than 72dB(A) when star type gear retarder
is used.When dynamic retarder is used, its
noise level is the same withlow noise type products.
2.The listed cooled
water volume is measured when ball watery
temperature is t=27℃ and t=28℃,
other conditions see the follow: when
water reduced temperature Δt=10℃, the flow-in water temperature t1=43℃, flow-out water volume t2=33℃. When water reduced temperature Δt=20℃ and 25℃ ,
flow-in water temperature t1 is 60 and 55℃,
flow-out water temperature t2=35℃.
3.Water pressure is
measure at the pipeline connection. As
1kgt/cm2=9.8×104Pa, the water pressure of
this type products is between 0.3 to
0.5kgt/cm2.
Installation
size of DBL3 GBNL3 cooling tower
Type
L
L1
L2
R0
ф0
ф1
ф2
ф3
ф4
R
B
b1
b2
Dg1
Dg2
Dg3
Dg4
Dg5
Dg6
GBNL3
DBNL3
12
2033
1783
100
-
1210
1100
700
550
300
-
-
70
80
25
15
15
25
20
2123
1873
100
-
1460
1350
800
660
300
-
-
70
80
25
15
15
25
30
2342
2044
100
-
1912
1800
1200
820
400
-
-
80
100
25
15
15
25
40
2842
2542
100
-
1912
1800
1200
820
400
-
-
80
100
25
20
20
25
50
2830
2530
100
-
2215
2100
1400
985
500
-
-
100
125
32
20
20
25
60
3080
2780
100
-
2215
2100
1400
985
500
-
-
100
125
32
20
20
25
70
3194
2790
400
-
2629
2500
1600
1214
800
-
-
150
200
40
20
20
40
80
3440
3040
400
-
2629
2500
1600
1214
800
-
-
150
200
40
20
20
40
70
100
3426
2926
400
-
3134
3000
1800
1415
1100
-
-
150
200
40
20
20
40
80
125
3676
3276
400
-
3134
3000
1800
1415
1100
-
-
150
200
40
20
20
40
100
150
3753
3353
200
-
3732
3600
2400
410
450
1836
-
300
320
200
250
80
25
25
50
125
175
3803
3603
200
-
3732
3600
2400
410
450
1836
-
300
320
200
250
80
25
25
50
150
200
3835
3615
220
-
4342
4200
2800
460
500
2193
-
350
370
200
250
80
32
32
50
175
250
4085
3865
220
-
4342
4200
2800
460
500
2193
-
350
370
200
250
80
32
32
50
200
300
4223
3993
230
-
5134
5000
3400
540
600
2606
-
460
460
250
300
80
40
40
50
250
350
4473
4243
230
-
5134
5000
3400
540
600
2606
-
460
460
250
300
80
40
40
50
300
400
4618
4388
230
-
6044
5900
3800
580
640
3030
-
460
460
250
300
100
50
50
50
350
450
4868
4638
230
-
6044
5900
3800
580
640
3030
-
460
460
250
300
100
50
50
50
400
500
5219
4913
300
-
6746
6600
4200
660
720
3369
-
560
560
300
350
100
50
50
80
450
600
5719
5419
300
-
6746
6600
4200
660
720
3369
-
560
560
300
350
100
50
50
80
500
700
5889
5589
300
-
7766
7600
5000
760
820
3890
-
560
560
350
400
100
80
80
80
600
800
6089
5789
300
-
7766
7600
6000
760
900
3890
-
560
560
350
400
100
80
80
80
700
900
6089
5740
300
-
8836
8600
6000
840
900
4422
-
650
650
400
450
100
80
80
80
800
1000
6580
6240
300
-
8836
8600
840
900
4422
-
650
650
400
100
80
80
80
Parameter of GBNL3