HL3-2A、PYHL-14A、HLF-6 High efficiency low noise mix flow fan
1.Briefing and features:
  HL3-2A low noise power saving mix flow fan and PYHL-14A low noise power saving fans for fire fighting and fume exhaust are new type of fans between axial and centrifugal fans. They have larger flow volume than centrifugal fans and high air pressure than axial fans, high efficiency, power saving, low noise and conveniently installation. The fan is mainly composed of impeller, air funnel, opening air collector, guide vane , motor and etc. the impeller adopts meridional accelerated distorted vanes which welded on the hub, and possess fine pneumatic performance after the balance test.
2.Usage :
  HL3-2A mix flow fans are generally used to ventilation; PYHL-14A mix flow fire fighting and fume exhaust fans could be used to exchange high temperature fume as well as to ventilation. It could continuously work for 60min in 300, suit to exchange fume of tunnel, underground garage, underground shop, underground store and advance building. When there is on fire, the smoke could be exhausted in time and also the ideal companion products for fire fighting. This type fans have been adopted by the hall of Zhongnanhai, Beijing Zhongguancun, Shanghai oriental bear TV station, Dalian Olympic project, Shenzhen Wanhao Five star hotel, Xiamen Atlantic sea view town and etc.
3.Performance choice
  1. the listed performance is the one under the highest efficiency, there are five different performance points, you can refer to the performance table when choosing.  The total pressure aberration of quality passed products is less than ±5. This performance table is the parameter measured in standard situation. All the performance in document or in ordering list should the standard one.
    2. the fan could be installed standing or lying. If there are special requirements for flow volume, pressure, installation dimension, we could re-design the fan for you.
    3. the listed noise level refers to the pipeline installed fan noise.
4. Installation and using of mix flow fan
   1.when install the fan, make sure all the apparatus is ok and connection part is fasten.
    2.Horizontal installed. Adjust the contact section of fan with the ground basic and connections with the air out pipeline, making them connected naturally, but not connect them forcedly. Not put the pipeline on the fan instruments.
    3.Stop the running and check the fan when there is violent vibration and abnormal phenomenon.
    4.If fan is used outdoor, protection to avoid rain should be set. Clean the fan in certain time to anti-rust.

Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net
Office in Beijing Address Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone13589940048
Contact : An Shuwei