| HL3-2A、PYHL-14A、HLF-6 High
efficiency low noise mix flow fan |
| 1.Briefing and features: |
| HL3-2A low noise power
saving mix flow fan and PYHL-14A low noise power saving
fans for fire fighting and fume exhaust are new type of
fans between axial and centrifugal fans. They have larger
flow volume than centrifugal fans and high air pressure
than axial fans, high efficiency, power saving, low noise
and conveniently installation. The fan is mainly composed
of impeller, air funnel, opening air collector, guide vane
, motor and etc. the impeller adopts meridional
accelerated distorted vanes which welded on the hub, and
possess fine pneumatic performance after the balance test. |
| 2.Usage : |
| HL3-2A mix flow fans
are generally used to ventilation; PYHL-14A mix flow fire
fighting and fume exhaust fans could be used to exchange
high temperature fume as well as to ventilation. It could
continuously work for 60min in 300℃, suit to exchange fume of tunnel, underground
garage, underground shop, underground store and advance
building. When there is on fire, the smoke could be
exhausted in time and also the ideal companion products
for fire fighting. This type fans have been adopted by the
hall of Zhongnanhai, Beijing Zhongguancun, Shanghai
oriental bear TV station, Dalian Olympic project, Shenzhen
Wanhao Five star hotel, Xiamen Atlantic sea view town and
etc. |
| 3.Performance choice |
1. the listed
performance is the one under the highest efficiency, there
are five different performance points, you can refer to
the performance table when choosing. The
total pressure aberration of quality passed products is
less than ±5%.
This performance table is the parameter measured in
standard situation. All the performance in document or in
ordering list should the standard one.
2. the fan could be
installed standing or lying. If there are special
requirements for flow volume, pressure, installation
dimension, we could re-design the fan for you.
3. the listed noise
level refers to the pipeline installed fan noise. |
| 4. Installation and
using of mix flow fan |
1.when install the fan,
make sure all the apparatus is ok and connection part is
fasten.
2.Horizontal installed.
Adjust the contact section of fan with the ground basic
and connections with the air out pipeline, making them
connected naturally, but not connect them forcedly. Not
put the pipeline on the fan instruments.
3.Stop the running and
check the fan when there is violent vibration and abnormal
phenomenon.
4.If fan is used outdoor,
protection to avoid rain should be set. Clean the fan in
certain time to anti-rust.
|
Performance parameter of mix flow fan
|
|
|
|
|
|
|
|
| |
Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net |
Office in Beijing Address: Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun |
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu |
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an |
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone:13589940048
Contact : An Shuwei |
|
|
|
|