9-19、9-26 series high pressure centrifugal fan
9-19、9-26 series high pressure centrifugal fan Usage and type:
  Generally used for the metallurgy furnace and high pressure imperative ventilation. Widely used to transmit materials, air and unselfburn、unharmful、erosionless gas. No stick material in the gas, the dust and grain containing level less than 15mg/m3, temperature lower than 80℃. To avoid the friction spark during transmitting easily explored and burned gas, we could adopt embossed aluminum impeller and explore-control motor. Their performance and parameter are the same with the general fans.
  9-19、9-26 series high stress centrifugal ventilator could be made into LG and RD types. Viewing from the one motor side, if the impellers rotate clockwise, it is called right hand ventilator .if the impellers rotate anti-clockwise, it is called left hand ventilator. The outlet place is shown by the outlet angle of the shell.
  9-19、9-26 series high pressure centrifugal fans are single inlet type, contain №.4~16 thirteen types, among which №.4~6.3 belong to type A driven , №.7.1~16 belong to type D driven.

Diagram of the fan outlet place
№.4~6.3 fans in 9-19、9-26 series high pressure centrifugal fans are mainly composed by impellers, shell, inlet cone matched with distributed direct connection motor; besides the components above, №.7.1-16 also posses transmission part.
1)1) impeller: type 9-19 has twelve impellers, type 9-26 have sixteen impellers, all of them are 、front curved vane. After shaped and dynamic balance adjustment, they are with good pneumatic performance, high efficiency and stable running.
2)2) shell : all-continued welded adopting high-quality steel
3)3) Air inlet made in whole was set in one side of the fan , the section parallel with the shaft is curve, which could let the air in freely with less loss.
4)4) Actuating part: made up by main shaft, bearing case and shaft connection equipment.
9-19、9-26 series high pressure centrifugal fan Performance and option  
  The performance is measured under standard condition. All the performance parameters in technology documents or ordering requirements are considered the standard ones. So in the un-standard conditions, you should transform the parameters into the standard ones.
according the follow formula :Q1/Q2=nl/n2; P1/P2=(nl/n2)2(ρ1/ρ2)(Pa1/Pa2)[(273+t2)/(273+t1)]
N1/N2=(nl/n2)3(ρ1/ρ2)[(273+t2)/(273+t1)]; η1=η2。
in the formula:Q-flow volume (m3/h) N-power(kw) p-density(kg/m3) t-temperature(℃)
p-total pressure(Pa) η-efficiency(%) n-speed(r/m) Pa- atmosphere(Pa0
Note: footnote‘2’ refers to the known performance and parameters, ‘1’ refers to the wanted performance parameters Atmosphere Pa=101325Pa, temperature t=20℃, the atom condition in the relative humidity φ=50%, air density η=1.2kg/m3, gravitation acceleration g=9.8m/s2 in standard condition. 。
 9-19、9-26 series high pressure centrifugal fan Performance and option table
performance and apparatus option table of 9-19 series high pressure centrifugal fan 1


Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net
Office in Beijing Address Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone13589940048
Contact : An Shuwei