SR900 electric or  pedal driving fan
1.Usage of SR900 electricity or pedal driving fan
  SR900 electricity or pedal driving fan could be used for the ventilation of underground air raid shelter. When the electricity supply is ok, drive the fan by electricity; when the electricity supply is cut, drive the fan by man force.
2.Main technology parameter of SR900 electricity or pedal driving fan
  1.electric driving
  Rotation speed 2900r/m, flow volume 900~1650m3/h
  Flow volume 22801450Pa(2326148mm mercury pole)
  Rotation speed 2840r/m, flow volume 900~1650m3/h
  Flow volume 20401140Pa(2326148mm mercury pole)
  2.pedal driving
  Rotation speed 2000r/m
  Flow volume 900m3/h
  3.noise level

Acoustic frequency  (Hz) (db)

Noise level (dB)

31.5
63
125
250
500
1000
2000
4000
8000
1600
A
B
C
L
70
79
79
81
83
81
78
72
61
51
85
87
88
89
  One man could supply power 0.28Kw by pedal, so two men could give power 0.56Kw, the real power is measured 0.54Kw. one strong man could continuously pedal ten minutes. The member turning schedule should be arranged in professional air defence bridge. There are left 90°and right 90°two type fans.
3.Installation and usage of SR900 pedal or electricity driving fan
  1. make sure nothing is left in the fan, and every part of the fan is fastened connected and flexible. If trouble exists, dispose it in time.
  2. Horizonnal install the fan, the flow convey pipeline should not put on the fan shell.
  3. Check the fan immediately when abnormal phenomenon happens. The fan could only run when every apparatus and circuit is ok. The fan and pedestal could be dismounted, so it is easily carried into rooms.
  4. Discharge the V belt when drives the fan by pedal. The fan pedestal could be fastened by buried steel plank.
4.Maintenance of SR900 pedal or electricity driving fan
 1. Maintain the fan and exchange the lube in certain times. Maintain the fan totally after two-year 
 2. Check the bracket system, and make sure no part is rust or loose.
 3. If the fan will be free, uninstall the belt or loose the motor bracket to loose the belt.
5.Aspect dimension and installation size (diagram is right 90°)

Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net
Office in Beijing Address Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone13589940048
Contact : An Shuwei