DJF-1 Electric and pedal driving fan
1. DJF-1 pedal or electricity driving fan
    DJF-1 Electricity and pedal driving fan is the necessary equipment to filter poison gas in the air defense project or the antiaircraft basement in war when electricity is cut and atom, chemical or bacteria arms were adopted by enemies. In war time, it could be used to ventilation and air filter for four hundred people by man force. In peace time, it could be used to ventilation of air defense project , underground hotel, restaurant and shop.
2.Technology parameter of DJF-1 electric and pedal driving fan
  1.Pedal driving in the Wartime
  Pedaled by four men in the speed of n=40rh
  Flow volume: Q1200m3h
  The four men with normal physical force could continuously work for more than 20min
  2.In peace time
  Diving by Y90S-4 motor :motor voltage N=11KW, speed n=14r/h, power is three phase 380V
  Flow volume: Q=26003060m3/h
  Air pressure: (total pressure) P=9060mm mercury pole
3.Installation of DJF-1 electric and pedal fan
  1. Check over the connection part before installation, and make sure there is no impinge and abrasion phenomenon. Adjust the distance between air opening and impeller, and keep the horizontal position.
  2.If the fan frame is loose, you should assemble the frame according the DJF-1 fan model dimension diagram, fastening the eleven fan frame parts and speed acceleration case by still anchors making the two axes are concentric and set ??? on the hinge. The according maintain chapter of the instrument, shakedown the running of motor and the pedal alerting in different operation conditions.(the working condition handle is set on one side of speed acceleration case)
4.Maintenance of DJF-1 electric and pedal driven fan
  It is generally driven by electricity, only in war pedal is used. As the situation is impendence when pedal driving is used, so every running part should be maintained well in peace time.
  1. Make sure no oil leaking phenomenon happens in gear case. If it is needed, the seal pad should be changed.
  2. Add lube on chain, gear and sheave to anti-rust.
  3. Check the bracket system, and make sure no part is rust or loose.
  4. Gear case maintenance: if the lube in fear case goes bad, empty it and add No.120 oil in ; if the oil is not adequate, add it until the oil surface is on the same level with the down- section of axel. Then run the fan by one man to check whether there is friction or impinging noise. If all is ok, run the fan by four men for five minutes.If trouble exists, repair it or change appurtenances.
  5. If the fan will be free, uninstall the belt or loose the motor bracket to loose the belt.
Maintain the machine every three months. In hot weather, maintain it every one or two months.
5.The model dimension and installation size of DJF-1 electricity and pedal driven fan(the fan is designed left aspect,90°)

Dezhou Air Conditioner Equipment Co., Ltd.
Address: No.181,North Dongdi Road, Tianqu Industry Park ,Dezhou
TEL:0534—2356870 2358328
FAX:0534—2358326
huifeng888@263.net
w-hf@263.net
Office in Beijing Address Room 302,The unit 14,Jiayuanerli fengtai beijing
Ceil phone:13522964184 13520981127
Contact:Li Xian Tao Lui Wei Jun
Office in Zaoqiang
Address: Fiberglass Garden ,Zaoqiang Town,Hebei Province
TEL:0318—7056261
FAX:0318—7056261
Ceil phone:13583474833
Contact:Bei De Yu
Office in Shijiazhuang
Address: Room 301,the Third Unit, No. 31 Building, Yangang New District
FAX:0311-5877888
TEL:0311-6700382
Ceil phone:139-31983216
Contact: Yuan Jin'an
Office in Shenyang
Address: No.26 Nonliuzhonglu Rood.Tiexi Shenyang
Ceil phone13589940048
Contact : An Shuwei